최신 Project-Planning-Design 무료덤프 - NCARB ARE 5.0 Project Planning & Design (PPD)
During design development of a new motel, the owner receives a cost estimate which was higher than what they had budgeted for. The project descriptions are as follows:
* Number of units: Twenty
* Construction type: V-B
* Number of stories: Two
* Structural system: Light wood frame
* Mechanical system: Central air system
The client wants the architect to reduce the initial construction cost without sacrificing the potential return on investment.
* Number of units: Twenty
* Construction type: V-B
* Number of stories: Two
* Structural system: Light wood frame
* Mechanical system: Central air system
The client wants the architect to reduce the initial construction cost without sacrificing the potential return on investment.
정답: D
설명: (DumpTOP 회원만 볼 수 있음)
An elementary school requires a renovation, selective demolition, and a major addition in order to accommodate a growing student population. An architectural firm has prepared schematic design plans incorporating the school's increased programmatic needs, including an enlarged library, cafeteria, and gymnasium; a secure courtyard; and additional space for administrative offices and classrooms. The main entrance was relocated in order to improve the traffic and pedestrian flow at the beginning and end of the school day, and additional parking was provided to comply with current zoning requirements.
The existing single-story masonry building was built in 1950. Two small additions were built later: the north addition will be kept and repurposed, but the south addition will be demolished. The building contains asbestos and lead in roof soffits, floor tiles, pipe insulation, and window paint. All existing mechanical systems need to be replaced; new systems have not been selected.
Considerations for the renovation include:
* The relocated front entrance must be easily recognizable, highly visible, and secure.
* Interior and exterior materials need to be durable and maintainable in order to withstand frequent student abuse, but also economical due to strict budget limitations.
* Good indoor air quality and increased energy efficiency are priorities for the selection of mechanical equipment.
After completion, the entire school should look uniform, without a distinctive difference between the existing building and new addition.
Building information:
* Construction Type is II-B.
The following resources are available for your reference:
* Existing Plans, including site and floor plans
* Proposed Plans, including site and floor plans
* Cost Analysis
* Zoning Ordinance Excerpts, for off-street parking requirements
* IBC Excerpts, showing relevant code sections
* ADA Standards Excerpts, showing relevant sections from the ADA Standards for Accessible Design Which of the following is the maximum height the platform can be above the gymnasium floor per the proposed design?
The existing single-story masonry building was built in 1950. Two small additions were built later: the north addition will be kept and repurposed, but the south addition will be demolished. The building contains asbestos and lead in roof soffits, floor tiles, pipe insulation, and window paint. All existing mechanical systems need to be replaced; new systems have not been selected.
Considerations for the renovation include:
* The relocated front entrance must be easily recognizable, highly visible, and secure.
* Interior and exterior materials need to be durable and maintainable in order to withstand frequent student abuse, but also economical due to strict budget limitations.
* Good indoor air quality and increased energy efficiency are priorities for the selection of mechanical equipment.
After completion, the entire school should look uniform, without a distinctive difference between the existing building and new addition.
Building information:
* Construction Type is II-B.
The following resources are available for your reference:
* Existing Plans, including site and floor plans
* Proposed Plans, including site and floor plans
* Cost Analysis
* Zoning Ordinance Excerpts, for off-street parking requirements
* IBC Excerpts, showing relevant code sections
* ADA Standards Excerpts, showing relevant sections from the ADA Standards for Accessible Design Which of the following is the maximum height the platform can be above the gymnasium floor per the proposed design?
정답: A
설명: (DumpTOP 회원만 볼 수 있음)
Which of the following design elements will affect pedestrian security within a site? Check the four that apply.
정답: B,C,E,F
설명: (DumpTOP 회원만 볼 수 있음)
A church congregation has hired an architect to help them determine the feasibility of converting a retail strip mall space into a new church. The space is 30' wide and 125' long and is in an interior location with tenants on both long sides. The client has requested the following:
Natural light into the central gathering space
Nursery space for young children
Church office space
Adequate restrooms
Visually appealing landscaping
Which of the following should the architect consider to help determine if the project can move forward?
Check the three that apply.
Natural light into the central gathering space
Nursery space for young children
Church office space
Adequate restrooms
Visually appealing landscaping
Which of the following should the architect consider to help determine if the project can move forward?
Check the three that apply.
정답: B,D,E
설명: (DumpTOP 회원만 볼 수 있음)
An architect is designing overhangs for a building on a site in the southeastern United States. The architect desires to minimize heat gain during the summer months.
Click in the sun on the solar path diagram that the architect should consider when designing the overhangs.

Click in the sun on the solar path diagram that the architect should consider when designing the overhangs.

정답:

Explanation:
A diagram of solar path diagram AI-generated content may be incorrect.

* The solar path diagram shows the sun's trajectory through the sky at different times of the year.
* In the southeastern U.S., during summer months, the sun reaches a high altitude (near the top of the solar path diagram), typically toward the southern sky.
* Designing overhangs to block this high summer sun reduces direct solar heat gain inside the building, improving thermal comfort and reducing cooling loads.
* The lower sun position corresponds to winter when sunlight penetration is beneficial for passive solar heating and daylighting, so overhangs should allow low-angle winter sun while shading high-angle summer sun.
On the provided diagrams, the sun symbol at the highest arc near the south (the highest yellow sun on the upper diagram) represents the summer sun path to focus on for shading design.
When laying out access routes and parking lots for an office building, which of the following strategies can increase the security of the site?
정답: B
설명: (DumpTOP 회원만 볼 수 있음)